Extron electronic 300 TV Video Accessories User Manual


 
VN-Matrix 300 • Installation and Basic Setup Procedures 20
Network Port Specific Options
Option Function Comment
Unit Specific Options
8 Set the number of the
port that is used for
communications with
the system controller.
By default this is set to 5432, this may be changed if required.
Note that all VN-Matrix 300 units MUST have the same port
number assigned.
18 Set the port number
that is used for
communication with
the server.
By default this is set to 80, this may be changed if required.
Note that the browser in use must use the same port number.
9 Reboot and activate
settings.
Any changes made are only activated after a reboot of the
VN-Matrix 300 unit.
NOTE: Typing reboot at the hyperterminal
cursor will also reset the unit.
Network (NIC) Connections
All network connections are made at the rear panel of the VN-Matrix 300.
CAUTION: Do not proceed with connecting VN-Matrix 300 to an existing network until
it is correctly configured using the Low level configuration procedure.
Incorrect connection or configuration may cause disruption to other
network users.
Typically, the VN-Matrix 300 will connect to convenient network point on an existing in-
house network. Use the correct cable type for your chosen network.
Single Network Connection
The VN-Matrix 300 may be congured to run on a single physical network port (1 or 2). In
this configuration all data (image, ancillary and control including monitoring) is transported
over a single physical link.
The VN-Matrix 300 may be used over both switched (single segment) and routed
(multi-segment) networks.
Dual Network Connection
If required, both network connections may be used. In this configuration image and ancillary
data is transported on one connection whilst the other network port is used for monitoring
and or management functions.
System Control Data
System control is managed by the VN-Matrix 300 that has been designated as the controller.
Any changes made in the interface are sent to the affected VN-Matrix 300 device from the
controller. The control information between the controller and any other VN-Matrix 300 unit
in the system is sent via the network that has been assigned to the controller.