Extron electronic 300 TV Video Accessories User Manual


 
VN-Matrix 300 • Installation and Basic Setup Procedures 24
Routed Network Configuration Example
NOTES: This is an example of a routed network configuration.
Unit 1 is congured as the controller, on IP address 192.168.0.1.
The two VN-Matrix 300 units are connected across a WAN via an external
router.
A gateway IP address is now set on NIC port 2 (option 14).
Only 1 gateway may be assigned.
Image data is transported over NIC 2 (the SFP connector).
The port used for image data transfer is set in the WEB interface, described
later.
Browser control is available on either NIC
Enter the IP address of the appropriate NIC in the browser address bar.
A network management system connected via NIC 1 (RJ45).
This provides isolation between image and SNMP traffic.
NIC2:192.168.0.1
NIC1:172.28.0.1
NIC2:192.168.1.1
NIC1:172.29.1.1
Local NMS server
172.28.0.3
Browser address
192.168.0.1
Unit 1
Unit 2
Controller
Switch
Switch
Switch
Switch
Browser (NIC1)
172.28.0.4
192.168.0.250 192.168.1.250
Browser (NIC1)
172.29.1.4
Local NMS server
172.29.1.3
Local SNMP
Browser (NIC2)
192.168.0.3
Browser address
172.28.0.1
Unit 1
Network Port 1 (RJ45) Network Port 2 (SFP)
1 Boot method: static [dhcp] 11 Boot method: static [dhcp]
2 Address: 172.28.0.1 12 Address: 192.168.1.1
3 Netmask: 255.255.0.0 13 Netmask: 255.255.255.0
14 Gateway: 192.168.0.250
5 Broadcast: 15 Broadcast:
6 Mtu: 1500 16 Mtu: 1500
17 Controller ip: 192.168.0.1
8 Controller port: 5432 18 Webserver port: 80
9 Exit