VN-Matrix 300 • Installation and Basic Setup Procedures 21
Video and Audio Data
Video and audio data may be transported over either of the NICs on the VN-Matrix 300 unit
and are independent of the system control data.
NOTE: The browser is accessible via either network port on the unit that is configured
as the controller.
Switched Network Configuration, Example 1
NOTES: In this example, two VN-Matrix 300 units are congured to work across a
switched network.
Unit 1 is congured as the controller, on IP address 172.28.0.1.
This unit serves the management interface (GUI).
The browser (control) PC may be connected to either NIC.
System control data is always sent over the 172.28.x.x network
Image data is congured to run over NIC 1 (the RJ45 connector).
This is defined in the management interface, described later.
NIC2:192.168.0.1
NIC1:172.28.0.1
NIC2:192.168.0.2
NIC1:172.28.0.2
Switch
Local NMS server
172.28.0.3
Browser
172.28.0.4
Unit 1
Unit 2
Controller
Browser (NIC2)
192.168.0.3
Switch
Browser address
192.168.0.1
Browser address
172.28.0.1
Unit 1
Network Port 1 (RJ45) Network Port 2 (SFP)
0 Speed/Duplex:auto_10_100_1000 10 Speed/Duplex:Fiber_fixed_1000
1 Boot method: static [dhcp] 11 Boot method: static [dhcp]
2 Address: 172.28.0.1 12 Address: 192.168.0.1
3 Netmask: 255.255.0.0 13 Netmask: 255.255.255.0
4 Gateway: 14 Gateway:
5 Broadcast: 15 Broadcast:
6 Mtu: 1500 16 Mtu: 1500
7 Controller ip: 172.28.0.1
8 Controller port: 5432 18 Webserver port: 80
9 Exit