GE 0150-0193G DVR User Manual


 
0150-0193G 57 DVMRe Triplex
Audio Limitations:
1. To record audio at least one the unit’s video inputs must be set to record video at a rate of 1pps
or faster.
2. If all the cameras are set to EVENT mode and no events are occurring, no audio will be recorded
regardless of the event recording speed.
3.17 Communications
Use this menu to:
Configure the baud rates and settings for the RS232 ports.
Configure the network address for the RS485 network.
Configure the Ethernet address and networks settings.
q Main Menu Communications RS232
Select the Port you wish to configure and press the ENTER button.
Port 1
Use this menu to:
Enable/Disable POTS and configure the Modem initialization
string (POTS Setup).
Adjust the Baud rate.
POTS Setup
The default modem string (shown below) is for use with Hayes Accura 56k, Diamond Supra Express
56k, and 5686 US Robotics modems in their default conditions. Consult with the modem manual
before attempting to make any changes. It is strongly recommended that the modem initialization
string only be modified by a qualified technician.
POTS Setup
SEQ key selects character bank
‘1’ key inserts blank character
‘2’ key inserts selected character
@ABCDEFGHIJKLMNOPQRSTUVWXYZ[\]^
Modem Init String : AT&F1&K3M0E1Q0V1S0=0&R2&C1&D0&H1
POTS : DISABLE
[Default Modem String] [CANCEL] [OK]
RS485
Ethernet
RS232
Port 2
Port 1
Baud Rate
POTS Setup