GE X3.28 Satellite TV System User Manual


 
Protocol X DCA
Configuration Guide
GE Energy Services
Restricted A197-0CG-1.00-2
Full
25
F205: Echo mode is not supported by L061-0.
Cause:
There is an interface error between the DCA and the DCA engine.
The NVRAM has been corrupted.
Remedy:
Contact the Customer Service Department and report this error.
Download the configuration and restart the system.
A.2 Non-Fatal Error Messages
These messages indicate the application has encountered a non-fatal configuration error or a non-
fatal stage of process initialization failed. The application will not suspend as a whole, but rather
attempt to run in a limited or reduced capacity.
E101: Restart failed for <process_name>
Cause:
The DCA was unable to spawn and activate the process.
Remedy:
Note the process name and contact the Customer Service Department to report this error.
E102: Not enough memory!!!
Cause:
The DCA was unable to allocate enough memory to start the ANSI X3.28 DCA.
Remedy:
Reduce the amount of memory used by this or other applications in the system.
Contact the Customer Service Department and report this error.
E110: Unable to open <com_port>, status = <x>
Cause:
The DCA was unable to open the requested communication port.
Effect:
The ANSI X3.28 DCA will be unable to communicate over the specified communication
port, <com_port>.