Honeywell PVB6438NS Universal Remote User Manual


 
SPYDER® BACNET® PROGRAMMABLE CONTROLLERS
5 63-2689—05
IMPORTANT
Special precautions must be taken for dampers that
open in a CCW direction. The actuator is shipped with
its rotation direction set to CW to Open, which applies
to the damper direction in steps 1 and 2 above. If the
damper shaft rotates in the CCW direction to open, the
controller software must be programmed to change
the rotation to “Reverse to Open,” which applies to the
damper direction in steps 3 and 4 above.
IMPORTANT
It is advisable to leave the dampers in an open
position after installation to avoid the possibility of
over-pressurizing the duct work on fan startup. Use
the Declutch button (see Fig. 1 on page 3) to open the
box damper on controllers that are powered down, to
prevent over-pressurization in the duct work on fan
startup. To Declutch, press and hold the button to
disengage the motor. Turn the damper shaft until the
damper is open and release the button. When power
is restored to the controller, the controller
synchronizes the damper actuator, so that the damper
is in the correct position upon startup.
Mount Controller
NOTE: The controller may be wired before mounting to a
panel or DIN rail.
Terminal blocks are used to make all wiring connections to the
controller. Attach all wiring to the appropriate terminal blocks
(see “Wiring” on page 8).
Fig. 4. Panel mounting - controller dimensions in inches
(mm) for PUB1012S, PUB4024S and PVB4024NS only
(PUB4024S and PVB4024NS shown).
Fig. 5. Panel mounting - controller and actuator
dimensions in inches (mm) for PVB0000AS and
PVB4022AS only (PVB4022AS shown).
Fig. 6. Panel mounting - controller and actuator
dimensions in inches (mm) for PVB6436AS.
Fig. 7. Panel mounting - controller dimensions in inches (mm) for models PUB6438S and PVB6438NS.
M31531
NOTE: CONTROLLER CAN BE MOUNTED IN ANY ORIENTATION.
3/16 (4.5) PANEL MOUNTING HOLE (4X)
DEPTH IS 2-1/4 (57)
4-13/16 (122)
4-1/8 (105)
6-1/4
(159)
5-7/8
(149)
4-13/16 (122)
4-1/8 (105)
6-1/4
(159)
5-7/8
(149)
1 2 3 4 5 6 7 8 9
10
11
12
1 2 3 4 5 6 7 8 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
13
14
15
16
17
18
19
20
21
22
23
24
NOTE: CONTROLLER CAN BE MOUNTED IN ANY ORIENTATION.
M31532
8-9/32
(211)
1-15/16
(49)
6-9/32
(159)
3/16 (4.5) PANEL
MOUNTING HOLE (4X)
27/32
(21)
4-1/8
(105)
6-1/4
(159)
5-7/8
(149)
DEPTH IS
2-1/4 (57)
1 2 3 4 5 6 7 8 9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
1
2
3456
78
109 234567
11 111111
1
2
34
5
6
78
0
9
2
22
22
2
2
22
3
3
1
2
34
5
6
78
0
9
3
3
3
33
33
34
5-3/4
(146)
10-5/16 (262)
NOTE: CONTROLLER CAN BE MOUNTED IN ANY ORIENTATION.
PANEL MOUNTING HOLE
(4X) 3/16 IN. (4.5)
M29329
5-3/64
(128)
8-5/16 (211)
6-29/64 (164)
1-55/64
(47)
6-17/64
(159)
7/16
(11)
DEPTH IS
2-1/4 (57)
1
2
3 4 5 6
7 8
1 0 9 2 3 4 5 6 7 8 0 9
1 1 1 1 1 1 1 1 1 2 1
1
2
3 4
5
6
7 8
0
9
2
2 2
2 2
2
2
2 2
3
3
1
2
3 4
5
6
7 8
0
9
3
3
3
3 3
3 3
3 4
5-3/4
(146)
6-27/32 (174)
NOTE: CONTROLLER CAN BE MOUNTED IN ANY ORIENTATION.
PANEL MOUNTING HOLE
(4X) 29/64 IN. (12)
M29330
5-3/64
(128)
6-29/64 (164)
5-29/64
(139)
1
2
3 4 5 6
7 8
1 0 9 2 3 4 5 6 7 8 0 9
1 1 1 1 1 1 1 1 1 2 1
1
2
3 4
5
6
7 8
0
9
2
2 2
2 2
2
2
2 2
3
3
1
2
3 4
5
6
7 8
0
9
3
3
3
3 3
3 3
3 4
6-27/32 (174)
5-3/64
(128)
6-29/64 (164)
5-29/64
(139)
PVB6438NS
PUB6438S
DEPTH IS
2-1/4 (57)