LG Electronics 22LQ630H CRT Television User Manual


 
24
206-4207
Installer Menu (Cont.)
When Hospital Mode is set to 0 (disabled), both the IR code
that will control the TV and the speaker selection depend on the
Installer Menu item 020 FEATURE LEVEL setting.
Note: The default setting (254) is not selectable in the Installer
Menu. If you ever need to restore the default setting, you must set
item 117 FACT DEFAULT to 1 to reload the factory default settings.
See item 117 description for further information.
Note: In the Installer Menu, an informational code is displayed
at the right of each Hospital Mode value. Each code consists of
three characters. The rst character—T, P, or B—identies the
speaker: TV, Pillow, or Both. The second character—Z, P, R,
or D—identies the pillow speaker code: Zenith, Philips, RCA, or
Disabled. The third character—1 or 2—identies the bed number.
028 - CH. OVERIDE (Channel Override)
If set to 1, the user can select channels with either Channel Up/
Down or by direct keypad entry. If set to 0, only those channels
that are active in the TV’s memory can be selected.
029 - OLD OCV (On Command Video™)
Set to 1 for operation with systems from On Command Corporation.
030 - ACK MASK
MPI Communication Parameter. When set to 1, enables ACK
feature of MPI.
031 - POLL RATE
MPI Communication Parameter. Selects poll rate for MPI. Step
size of 16 ms. Changing from default may affect communication
via MPI.
032 - TIMING PULSE
MPI Communication Parameter. Sets baud rate for MPI. Step size
of 4.3 uS. Changing from default may affect communication via MPI.
035 - COMPPORT EN. (Computer Port Enable)
Set to 1 to enable display panel HDMI 1 input. Set to 0 to disable
display panel HDMI 1 input.
039 - REAR AUX EN. (Rear Aux Enable)
Set to 1 to enable display panel rear Aux (Video 1) input. Set to 0
to disable display panel rear Aux (Video 1) input.
046 - STRT AUX SRCE (Start Aux Source)
Sets the starting Aux source. When turned ON, the TV will tune to
starting Aux source if item 004 STRT CHANNEL is set to 0.
1 = Video 1 4 = RGB 255 = Last Aux
3 = HDMI 1 5 = HDMI 2
Note: Above is applicable only if all Aux sources are enabled.
Note: This item is not available in the Installer Menu unless item
004 STRT CHANNEL is set to 0.
047 - AUX STATUS
Set to 1 for MPI Aux source to be reported as a channel number
instead of channel 0. Set to 0 to disable Aux identication change.
Controls MPI status channel response for Aux inputs.
053 - DIS. CH-TIME (Disable Channel-Time)
Set to 1 to disable the Channel-Time display; Channel-Time dis-
play will not appear. Set to 0 to enable the Channel-Time display.
069 - EN. CH-T COL. (Enable Channel-Time Custom Color)
Set to 1 to enable custom color for the Channel-Time display. Set
to 0 to disable custom color for the Channel-Time display.
070 - FOR. CH-TIME (Channel-Time Display Foreground Color)
Set according to Color Chart:
0 = Black 3 = Cyan 6 = Yellow
1 = Blue 4 = Red 7 = White
2 = Green 5 = Violet
Note: If foreground color and background color are the same, the
menu background will be transparent.
Note: Applies only to “Channel Not Available” message if item
073 CH NOT AVBLE is set to 1 (enabled). Also, items 070 FOR.
CH-TIME and 071 BCK. CH-TIME are not available in the Installer
Menu when item 069 EN. CH-T COL. is set to 0.
071 - BCK. CH-TIME (Channel-Time Display Background Color)
See description for item 070 FOR. CH-TIME above. The color
chart is the same for both items.
073 - CH NOT AVBLE (Channel Not Available)
If set to 1 and item 028 CH. OVERIDE is set to 0, a “NOT AVAIL-
ABLE” message is displayed when a user direct tunes a channel
that is not in the channel scan list available in memory.
075 - REVERT CH (Revert to Start Channel)
If set to 1 and loss of MPI communication occurs, TV automati-
cally tunes to the specied Start Channel.
Note: This item is not available in the Installer Menu when item
004 STRT CHANNEL is set to 255.
077 - QUICK SHUTOFF
Allows end user (patient) to turn OFF TV using mechanical (analog)
Pillow Speaker Channel Up/Down buttons. Patient needs to press
and hold either channel button for time determined by value set. Set
to 0 to disable. Set from 1 to 17 to establish required hold time of
button—from 2 seconds to 10 seconds in half-second increments.
Note: This item is not available in the Installer Menu when item
013 SCAN MODE is set to 0.
078 - UPN MSB (UPN Most Signicant Byte)
User programmable number, most signicant byte readable by
MPI command. Note: Not linked to serial number.