39
206-4163
Reference: b-LAN Setup & Overview
The control device at the head end, for example, an LG FMA-LG101, can control multiple TVs. When the TV is
first installed, it must be turned ON in order for the head end to be able to communicate with the b-LAN. At this
point, if it is desired for the b-LAN to always be powered, including while the TV is in Standby, set Installer Menu
item 118 POWER SAVINGS to 001.
If the embedded b-LAN will not be used, enable maximum power savings in both Standby and TV Power On
Mode by setting Installer Menu item 118 POWER SAVINGS to 007.
POWER
SAVINGS
TV Power On State
TV Standby State
b-LAN Power
b-LAN Power
001 On On
003 (default) Off On
007 Off Off
The b-LAN module is internal to the TV. It allows the hotel/institution head end equipment to communicate, via
the institution’s RF distribution system, with the TV for configuration and control.
Note: MPI cards with b-LAN technology—LMT7Z5, LMT7Z7, LMT7Z9—are NOT supported on TVs in which the
b-LAN module is embedded.
Power to the b-LAN module is controlled by Installer Menu item 118 POWER SAVINGS. The default value is
003—the b-LAN module is only powered when the TV is turned ON. See chart below.