Mitsubishi Electronics HC1100 Projection Television User Manual


 
EN-28
Replacing the lamp
This projector is equipped with a lamp to project images. This lamp is a consumable. It may burn out or its
brightness may decrease during use. In such cases, replace the lamp with a new one as soon as possible. Be sure
to replace the lamp with a new lamp separately sold that is exclusive to this projector. Contact your dealer for
purchase of the lamp.
WARNING:
Be careful not to drop the lamp fixing screws into the inside of the projector. Dont put a metal piece or flam-
mable object into the projector. Using the projector with any foreign object present inside may result in elec-
tric shock or fire. When you cant remove the foreign object from the inside, contact your dealer for removal.
Be sure to install the lamp securely. When the lamp isnt installed properly, it wont illuminate. Improper
installation may also result in fire.
Dont shake the removed lamp or dont lift it above your face. You may be injured in your eye by flying or
falling glass fragments.
Dont replace the lamp immediately after use because the lamp cover is very hot. You may get burned. Turn off
the power using the POWER button. After the lamp goes out, wait about two minutes until the intake and
exhaust fans for cooling the lamp stop rotating. Then unplug the power cord, and wait at least one hour to
allow the lamp to cool down enough to the touch.
Interval of lamp replacement
The recommended interval of lamp replacement is about 2000 hours*
1
*
2
of consecutive use. Such interval differs
depending on the operating environment and may be shorter than 2000 hours*
1
*
2
. Decrease in luminescence
and/or color brightness indicates that the lamp needs to be replaced. When the lamp operation time exceeds 1500
hours*
1
, the indicator will blink alternately green and red while the lamp is lit (while the lamp is not lit, the
indicator will blink red only) and the lamp replacement message will appear on the screen for one minute
everytime the lamp is turned on. When the lamp has been used for about 1900 hours*
1
, the replacement message
(LAMP EXCHANGE) will appear on the screen for one minute every 10 hours*
1
thereafter.
When the lamp operation time exceeds 2000 hours*
1
*
2
, the projector automatically shuts off and
cant be used until the lamp is replaced and the lamp operation time is reset.
*
1
When LAMP MODE of the INSTALLATION menu is set to STANDARD. When it is set to LOW, this duration
will be extended.
*
2
When LAMP MODE is set to LOW, this duration will be extended up to 3000 hours.
Caution:
Dont remove the lamp for any purpose other than replacement. Unnecessary removal of the lamp may result
in a breakdown.
This projector uses a high-pressure mercury lamp as the light source. The high-pressure mercury lamp may
explode or fail to illuminate permanently because of an impact, scratch, or deterioration through use. The
period of time until explosion or permanent failure to illuminate varies considerably from lamp to lamp,
depending on operation conditions. Therefore, the lamp may explode soon after the start of use.
The possibility of explosion of the lamp increases if you use it beyond its replacement period. When the in-
struction of lamp replacement appears, replace it with a new one immediately even if the lamp is still lighting
normally.
When the high-pressure mercury lamp explodes, glass fragments will scatter inside or outside the lamp box
and the gas charged inside the lamp will diffuse inside or outside the projector. The gas inside the lamp
contains mercury. Be careful not to breathe it or avoid it from entering your eye or mouth. If you should
breathe it or if it should enter your eye or mouth, see a doctor immediately.
In the event that the high-pressure mercury lamp has exploded, glass fragments may have been scattered
inside the projector. Ask your dealer to replace the lamp and to inspect the inside of the projector. When you
clean or replace the lamp by yourself, be sure to hold the handle of the lamp. You may get injured by glass
fragments.
Dont replace the lamp with the projector installed on the ceiling. Glass fragments may fall from the projector,
entering your eye or mouth causing injury.
When placing the projector upside down to replace the lamp or conduct maintenance, ensure that the projec-
tor is securely placed before working with it.