Page 20
MODEL: WD-52327 / WD-62327
ELECTRICAL ADJUSTMENTS
Note: Perform only the adjustments required.
Do not attempt an alignment if proper equipment is not available.
Test Equipment
• Oscilloscope (Unless otherwise specified, use 10:1 probes)
• Signal Generator (NTSC Color Bar)
Test Signals
A. Internally Generated Square Pattern Signals
B. Color Bar Signal
Use the color bar signal shown
below, unless otherwise specified
in this manual.
1H
40%
40%
100%
75%
Split-Field Color Bars (100% window)