Omega Engineering RD8900 DVR User Manual


 
42
An example of Totalizer: A factory operates for 8 hours a day, and the staff wish to get the
total volume of production from daily, weekly and monthly reports. First, the user needs to
enter into Tools mode, do the settings as follows, then totalizer starts to work from 8:30 am,
and stops at 17:30 pm daily. After production has finished, the user does the following: press
Event key on the left hand side, and press Mode key to select Report mode. Finally, press
Report key to choose daily, weekly or monthly report.
Timer1
Type: Daily Action: Enable
Time - Hour: 8 Min: 30
Job1: Reset Totalz Target: Tolz1
Job2: Enable Totalz Target: Tolz1
Timer2
Type: Daily Action: Enable
Time - Hour: 17 Min: 30
Job1: Disable Totalz Target: Tolz1
Job2: Log Report Target: Tolz1
Totalizer
Name: xxxx Desc : xxxxxxxxxxxxxxxxx
Source: AI1 Action: Enable Decimal: 1
Period: Min Unit: xxxx Preset: 0.0
Event
No Type Setpoint Job1 Job2
1 Hi xxxx Log Alarm Set DO on
2 Low xxxx Log Alarm Set DO off
The Weekly Report shows the following information:
The week’s production volume: Monday: 990, Tuesday: 1010, Wednesday: 1020, Thursday:
1020, Friday: 980 respectively. The weekly report shows production volume 5,020.