2-2 Numeral Displays
Values from numeral tables can be displayed on a screen. The numeral table
entry to be referenced, the display position, and the manner of display are
set. You can set a maximum of 50 numeral displays per screen.
For the NT20M, numeral table entries are numbered from 0 to 127, for a total
of 128. For the NT600M, numeral table entries are numbered from 0 to 255,
for a total of 256.
The procedure for setting number displays depends on whether or not direct
connection is ON or OFF in the Tool Settings. Both procedures are given be-
low.
2-2-1 Normal Numeral Displays
Select NUM DISP from the Initial Edit Display, the Initial Display for Numeral
Display will appear.
Initial Display for Numeral Display
Only table number entries 0 to 13 are displayed first. To display the next en-
tries, press the Pg Dn Key; to return to previous entires, press the Pg Up
Key.
Select the numeral table entry that you want to reference and then press the
Enter Key.
Inputting Initial Values The initial value for the selected memory table reference is input next. Refer
to page 12 for details on input methods. You can input numbers from
–99999999 to 99999999. Numeral displays can display decimal numbers, but
you enter them here without the decimal point. For example, if you want to
Designating Numeral Table
References
Numeral Displays Section 2-2