39
OPERATION
Item Setting
No.
Superimposed
display
No.
Superimposed
display
Description of settings
Setup menus
163 REPT MODE
0000
0001
0002
FREEZE
BLACK
SW
For setting what images are to be output while the tape returns to the BEGIN point
in the repeat playback mode.
0: The tape returns to the BEGIN point with the image played back at the END
point still frozen.
1: The tape returns to the BEGIN point while the screen remains black.
2: The tape returns to the BEGIN point following the setting selected by the
TAPE/EE switch.
<Note>
If the tape end is set as the END point when “0:FREEZE” is selected, the playback
image will not be frozen properly.
Set the END point to a place within the range where images are recorded.
180 BATTERY SEL
0000
0001
0002
0003
0004
0005
0006
NiCd12
NiCd13
NiCd14
S-LION
I-LION
TYPE-A
TYPE-B
For setting the type of battery.
0: 12 V-type battery
1: 13 V-type battery
2: 14 V-type battery
3: Setting for using the BP-L90A lithium-ion battery.
4: Setting for using the ENDURA80 lithium-ion battery.
5: Setting for using the battery selected by the menu item No.181 [TYPE-A NEAR]
item and No.182 [TYPE-A END] item
6: Setting for using the battery selected by the menu item No.183 [TYPE-B NEAR]
item and No.184 [TYPE-B END] item
“
” indicates the factory setting.
181 TYPE-A NEAR 0000
:
0044
10.6
:
15.0
For setting (in increments of 0.1 V) the voltage level at which the counter flashes as
warning for TYPE-A battery (selected as the menu item No.180 [BATTERY SEL]
item).
<Note>
When this item has been set to a voltage level close to 15.0 V, the counter display
may flash even when an AC power source is being used.
182 TYPE-A END 0000
:
0034
10.6
:
14.0
For setting (in increments of 0.1 V) the voltage level at which the TYPE-A battery
(selected as the menu item No.180 [BATTERY SEL] item) is to be automatically
turned off.
183 TYPE-B NEAR 0000
:
0044
10.6
:
15.0
For setting (in increments of 0.1 V) the voltage level at which the counter flashes as
warning for TYPE-B battery (selected as the menu item No.180 [BATTERY SEL]
item).
<Note>
When this item has been set to a voltage level close to 15.0 V, the counter display
may flash even when an AC power source is being used.
184 TYPE-B END 0000
:
0034
10.6
:
14.0
For setting (in increments of 0.1 V) the voltage level at which the TYPE-B battery
(selected as the menu item No.180 [BATTERY SEL] item) is to be automatically
turned off.
161 CTL BGN
or
TC BGN
For setting the BEGIN point in the repeat playback mode.
Either TC or CTL is set as the counter display mode using the COUNTER button.
If no mode is set, – – : – – : – – : – – appears, and the tape start serves as the
BEGIN point.
162 END For setting the END point in the repeat playback mode.
Either TC or CTL is set as the counter display mode using the COUNTER button.
If no mode is set, – – : – – : – – : – – appears, and the tape end serves as the END
point.