88
■ Internal Timer Recording
The internal timer recording begins when the reserved start
time comes, and continues until the reserved end time is
reached.
The reservations are made in the TIMER REC SETUP menu,
and the TIMER parameter is set to INT in the WJ-HD500
SETUP menu.
As described before, the received video inputs can be
assigned to four groups, and those groups are assigned to
the programmed timer.
It enables the use of different recording modes for each
group (Time Lapse, Multi Shot or One Shot), depending on
the requirements for the surveillance environment.
■ Power-on Time Lapse Recording
The Disk Recorder can record images at the specific time
every day, using the timer switch that controls the AC mains
supplied to the Disk Recorder.
When the Disk Recorder is powered-on, the Time Lapse
Recording mode is activated, and records the data in the
manual recording space.
To use this function, set the TIMER parameter to EXT in the
WJ-HD500 SETUP menu.
■ Manual Recording
The video signal supplied to the VIDEO IN connectors is
recorded in Time Lapse Recording mode with the parame-
ters which were preset in the MANUAL REC SETUP menu:
recording mode, field rate and image quality.
The following procedure describes how to record manually
in the selected mode.
Note: When the TIMER parameter is set to something other
than OFF in the WJ-HD500 SETUP menu, the Disk
Recorder does not start recording even if the REC but-
ton is pressed.
1. Press the REC button to start recording.
REC ✽✽% is displayed on the Multiscreen Monitor.
(✽✽% indicates the remaining space of the Hard Disk.)
2. To stop recording, press the REC STOP button.
HDD
Manual Recorder
Manual Recorder
Group 1
Timer
Recorder
Group 2
Group 3
Group 4
Emergency Recorder
REC
REC STOP
Digital Disk
R
ecorder
W
J-HD
500
Timer
Switch
•
•
•
AC Outlet
F
S
16
RECORDING
HDD
Timer Recorder
Manual Recorder
Emergency Recorder
Group 1
Timer
Recorder
Group 2
Group 3
Group 4
HDD
Manual Recorder
Manual Recorder
Group 1
Timer
Recorder
Group 2
Group 3
Group 4
Emergency Recorder