90
• Set to ALM-PRI
Records the alarm-activated input images preferentially over other video inputs.
• Set to ALM-ONLY
Records the particular images that have activated the alarm.
• Set to ALM-MULTI
• Records alarm images and creates thumbnails of images that have most recently received an alarm.
• Records alarm images that is chosen detecting the rest of alarm duration every alarm inputs.
• Records alarm images according to the REC RATE(BASE) in evenly until reaches REC RATE(MAX). Then the
sum exceeds the maximum recording rate, it records images at maximum rate.
● Alarm Recording for Internal Timer Modes
As described before, there are three recording modes for Timer Recording: Time Lapse, Multi Shot and One Shot Recording.
Two of these, Multi Shot and One Shot recording, are event-recording functions reacting to an alarm input. Therefore, there is
no difference compared to an alarm recording.
The procedure described below is an example for alarm recording in the Time Lapse Recording mode.
• Time Lapse Recording
When the Time Lapse Recording mode is selected for Timer recording, it records the alarm-activated images in this mode
with the specified recording rate, image quality and duration, as shown below.
The recording pattern varies according to the setting of the Dynamic Recording parameter (DYNAMIC REC).
(If the camera inputs 2, 4 and 5 are assigned to a group.)
• Set to OFF
Records the group input images in sequence starting with the lower number of the video input.