Pentair CP-100 Universal Remote User Manual


 
TROUBLE-SHOOTING
Your Control System is designed
to
provide yew
of
trouble-free pool and
spa
cnjoymcn1. Howcver,
iT
a1
any time your System should behave
erndcally,
consult the fallowing Check
List,
which should hclp to
alleviate
any problems caused by operator error.
If
you
are
sdll unuble to solve your pwtictllar symptom,
wfer
the
situation to a qualified Pool Service Company.
GENERAL
1.
Check all circuit breakers
at
elecrrical sub-panel.
2.
At
the
Power Center. ensure that all
the
Servfte
Switcbes
are
in
the
"AIJTO"
position.
NOTHING
QPERATES
I.
Check
3-amp
circuit brcllker which is
located
above
FILTER
PUMP
TLmc
Clock in
Power Center.
Tripped
circuit breaker is indicated
by
a
white
ub.
Push to reset.
2.
If
circuit b~pker continues
to
trip, refer
to
a qualified Service Company.
FILTER
PUMP
DOES
NOT
QPERATE
I.
At
the
Power Center, check that
the
FILTER
PUMP
Time
Clock
is
programmed on.
2.
Turn
the
FlLTER
Service
Switch
to
the
"ON"
position.
If
the
pump
still doesn't opentc,
consult a qualified Service Company.
FILTER
PUMP
DOES
NOT
TURN
OFF
1.
At
the Power Center, check that
thc
FILTER
Service
Switch
is
no1
in
the
"ON"
position.
2.
Check
that
tho
PUMP
BELAY
Status
Lighl
is
not
on,
indicating
that
the
System
is
~nning
its
4-minute cool down cycle.
3.
Check
thnt
the
POOL
CLEANER
Time
Clock
is
not programtned
on,
nutomatically
forcing the filter pump on.
4.
Turn
the
FfLTER
Service
Switch
to
the
"OFF"
pnsidan,
If
the
pump csntinucs
to
run,
consult a qualified Service Company.
POOL
CLEANER
DOES
NOT
QPERATE
1.
At rhs Power Cenrer, chcck that the
POOL
CLEANER
Ttme
Clock
is
programtned
on.
2.
At
the
Indoor Controller,
make
suro
that
Pushbutton
#S
(SPA)
is
not turnsd
on.
3.
Pool cleaner pump may require servicing.
mATEH
DOES
NOT
OPERATE
I.
Make
sun
that
film
pump is running.
2.
Check heater thermostat setting and pilot
light
(if
applicable).
3.
Check filter pmssu~.
If
filter
is
clogged. thc heater
may
not
br:
getling sufficient water
flow.
4,
Heater may
quire
servicing.
SPA
WATER
LEVEL
DROPS
I.
At
the Power Cenrer, check that the
SPA
Service
Switch
is
in the
"AUTO
position.
2.
Check
that
Motorized
Valves rotate in both directions
by
adjusting
toggle switch on the
rear
of
each
Valve
Actuators. Remember to return switches Ia their original position after
testing.
3.
A
"check valve"
in
the system
may
be
leaking.
Refer to
a
qualified Service Company,