122
12) Checking the inside temperature
A temperature level display is provided to make it possible to easily check the internal temperature of the main unit.
When GREEN is displayed = The internal temperature is OK.
When YELLOW or RED = The internal temperature is rather high. Turn the power supply to the set
is displayed off, check the installation conditions immediately, and then take measures
to dissipate heat through air conditioning etc.
When checking on the temperature, perform aging thoroughly, just as before adjustment. (A minimum of
30 minutes with a 100-percent white signal.) Do the same after checking on the effectiveness of heat
dissipation measures.
For more information, refer to Chapter 3, “Installation”.
1 Enter the integrator mode (refer to section 5.4.1, “About
the integrator mode”).
The ID number of the unit of adjustment items will be indicated
in the upper right corner of the screen, where “– –” is displayed
in the illustration.
Select OPTION 2.
2 Select “TEMPERATURE” to check on the unit's internal
temperature.
Select EXIT in screen 2 to return to screen 1.
WHITE BAL.
MENU
SCREEN
PICTURE
SIDE MASK
OPTION 1
3OPTION 2
SUB VOLUME
ALL DEFAULT
– –
OPTION 2
EXIT
– –
BAUD RATE : 4 8 0 0 BPS
FULL MASK : OFF
FAN CONTROL : AUTO
TEMPERATURE :
3OSD : ON
HOUR METER : 3 4 5 HRS
Integrator Mode
13) Checking the accumulated ON time
This function displays the accumulated time during which power has been flowing into the unit (in 1 hour units).
Time when the unit is in standby mode is not included in the accumulated ON time.
1 Enter the integrator mode (refer to section 5.4.1, “About
the integrator mode”).
The ID number of the set of adjustment items will be indicated
in the upper right corner of the screen, where “– –” is displayed
in the illustration.
Select OPTION 2.
2 Select “HOUR METER” to check on the unit's accumulated
ON time.
Select EXIT in screen 2 to return to screen 1.
WHITE BAL.
MENU
SCREEN
PICTURE
SIDE MASK
OPTION 1
3OPTION 2
SUB VOLUME
ALL DEFAULT
– –
OPTION 2
EXIT
– –
BAUD RATE : 4 8 0 0 BPS
FULL MASK : OFF
FAN CONTROL : AUTO
TEMPERATURE :
3OSD : ON
HOUR METER : 3 4 5 HRS
CAUTION
]
Screen 1
]
Screen 2
CAUTION
]
Screen 1
]
Screen 2