Runco DTV-943 CRT Television User Manual


 
APX-15
EYE-Q
TM
DIAGNOSTICS
This option allows a check-up of the EYE-Q
TM
NOTE: Most errors that occur during the LEARN REFERENCE
procedure or the beginning of the AUTOCONVERGENCE pro-
cedure are caused by one of the following:
Lens cap not removed
Lens focus not performed properly
Camera focus not performed properly
Ambient light is too high
Reference not learned properly
If all else fails, run the diagnostics.
To start up the EYE-Q
TM
Diagnostics:
Highlight EYE-Q
TM
by pushing up or down keys of the con-
trol disc;
Press the <ENTER> button.
After the <ENTER> button is pressed, the EYE-Q
TM
DIAGNOS-
TICS menu will be displayed and the Tests start instantly.
It includes check-ups on four items:
Interface Test;
Generic Test;
Sync Test;
Ram Test.
After completing each test, the status report will give the test
result:
Pass; or
Failed plus the error number.
During the Interface Test, the following messages will displayed
one after another on the screen:
Ready and Config Test;
Ready and Config OK;
Config Ackn. Test;
Config Ackn. OK;
Full Config Test;
Full Config OK;
Interface Test OK.
In case of failures, the error message will be shown:
FAILED... Error 01; or
FAILED... Error 02; or
FAILED... Error 03;.
During the Generic Test, the following messages will be displayed
one after another on the screen:
Config for Generic;
Config for Generic OK;
Chipselects Test;
Chipselects OK;
Addressability Test;