Sanyo dsr-3706pa DVR User Manual


 
English
Recording settings
How to set 60
This menu is used to extend the duration of the alarm
recording and to set the display method when an alarm
occurs.
1 ALARM RETRIGGER
This setting controls whether the recording duration will be
extended when another alarm is detected on the same
channel that is currently performing alarm recording.
(1) If a second alarm is detected during DURATION
operation on the same channel the recording time is
prolonged by the number of minutes set in
DURATION from the point when the second alarm
was detected.
(2) If another channel detects a second alarm during
DURATION operation and the same channel detects
a third alarm the first alarm recording finishes when
the third alarm is detected and the third alarm
recording starts. If the alarm is detected on another
channel (CH5), the recording takes place as set in
DURATION.
(1) Within the set DURATION, alarms detected by the
same channel are not acknowledged, therefore the
recording stops at the end of the DURATION.
However, the second alarm recording is recorded in
the first alarm recording.
(2) If another channel detects a second alarm during
DURATION operation and the same channel detects
a third alarm, the first alarm recording finishes when
the third alarm is detected and the third alarm
recording starts. If another alarm is detected on
another channel (CH5), the recording takes place as
set in DURATION.
2 MAIN MON. DISPLAY
Selects the screen type to use for display when an alarm is
detected.
NC:
The main monitor will not change, even if an alarm is
detected.
FULL: When an alarm is detected, the main monitor will display
the video from that channel in full-screen mode.
6: When an alarm is detected, the main monitor will change to
multi-6 screen mode.
3 ALARM PRIORITY (display when multiple alarms are
detected)
Sets the priority for alarm display to use when multiple
alarms are overlapping.
LAST:
When multiple alarms are overlapping, display is
performed in the priority order. The most recent alarm is
given first priority, then the one detected before that, and
so on.
FIRST: When multiple alarms are overlapping, only the alarm
detected first will be displayed. Alarms detected after that
will not be displayed.
However, if the duration of the first alarm is over, alarms
that have remaining durations will be displayed in the
order of detection.
SWITCH: When multiple alarms are overlapping, the alarms will
be displayed in a scrolling fashion, showing each
alarm video for one second.
4 MON. 2 DISPLAY
Selects whether the monitor connected to the MON2
terminal will be used to display the alarm video.
NC:
When an alarm is detected, the alarm video will not be
displayed on monitor 2.
SWITCH: When multiple alarms are overlapping, the alarms will
be displayed in a scrolling fashion, showing each
alarm video for one second.
LAST: When multiple alarms are overlapping, display is
performed in the priority order. The most recent alarm is
given first priority, then the one detected before that, and
so on.
FIRST: When multiple alarms are overlapping, only the alarm
detected first will be displayed. Alarms detected after that
will not be displayed.
However, if the duration of the first alarm is over, alarms
that have remaining durations will be displayed in the
order of detection.
H Alarm operation settings menu description
When setting "ON"
When setting "OFF"
<ALARM OPERATION SET>
ALARM RETRIGGER : OFF
MAIN MON. DISPLAY : FULL
ALARM PRIORITY : LAST
MON.2 DISPLAY : NC
1
2
4
3
1st Alarm detected 2nd Alarm detected
CH1
ALARM NO. 1
DURATION
1st Alarm detected 3rd Alarm detected
CH1
ALARM NO. 3
DURATION
ALARM NO. 1
CH5 ALARM NO. 2
2nd Alarm detected
1st Alarm detected 2nd Alarm detected
CH1
ALARM NO. 1
DURATION
1st Alarm detected 3rd Alarm detected
CH1
ALARM NO. 1
DURATION
CH5 ALARM NO. 2
2nd Alarm detected
L8HBM_XE(HARD)(GB).book 60 ページ 2006年2月6日 月曜日 午前10時52分