Sony PFM-42B1E Flat Panel Television User Manual


 
3-11
PFM-42B1, PFM-42B1E
(25)AUTO PLL
Whether the user menu adjustment PIXEL ADJUST is
enabled or disabled, is set.
ON : The user menu adjustment PIXEL ADJUST is
enabled.
OFF : All items of the adjustment PIXEL ADJUST
show the indication [___]. The user menu
adjustment PIXEL ADJUST is disabled.
Select the OFF position when the setup of the TOTAL
H and that of RESOLUTION do not agree with
specifications of the actual input signal.
(26)SYNC WIDTH (µs)
Sync pulse width of the horizontal sync signal is set in
units of microseconds [µseconds].
This menu item is prepared for the purpose of stabili-
zation of the sync signal separation circuit. Therefore,
accurate setting is not necessarily needed.
If the sync signal width is not known, select Not set
(source data).
c) SAVE AREA SELECT
Menu Structure
The data that is copied in the Editing RAM, is saved in the
preset area.
(1) SAVE AREA SELECT
Select the desired preset area from Table 1 to which
the content of the Editing RAM is saved.
(2) DATA SAVE
Execute to save the data to the preset area that is
selected by the SAVE AREA SELECT. Change the
item from CANCEL to EXECUTE. Then press
ENTER.
Note : Judgment whether the input signal agrees with the preset data or not,
is performed using the horizontal sync frequency, vertical sync
frequency and polarity of the sync signals. If the same sync signal
already exists in the preset area (Table 1), the specification that has
the small preset No., has a higher priority.
SAVE AREA SELECT
SAVE AREA
DATA SAVE
: PROGRAM1
(1) Select the
desired preset
area to which
the data is saved.
(2) Execute to
save the data.
7. MAINTENANCE
Menu Structure
The data that is unique to the particular machine of the
PFM-42B1/B1E
and the scan converter can be upgraded
using this menu.
a) WATCH ERROR
Errors of the built-in watch IC can be corrected.
To correct the error, enter the measurement value of
the frequency counter that is connected.
Range of adjustment is from 32761.85 Hz to 32774.25
Hz.
b) MODEL NAME
Model name can be set.
c) SERIAL No.
Serial number can be set.
d) SC PROG LOAD
The built-in program of the scan converter can be
modified using this menu item.
Change the item from CANCEL to EXECUTE. Then
press ENTER.
Watch Error Adjustment
Refer to section 3-6. Watch Error Adjustment.
MAINTENANCE
WATCH ERROR
MODEL NAME
SERIAL No.
SC PROG LOAD