FIVE Monitor Functional Description 4.9
i
SSOOLLOO
The SOLO button is conveniently located below the fader, and provides a mono
PFL or stereo AFL feed to the engineers headphones or monitors depending on
the mode selection at the Master section. The SOLO button can also be activated
remotely from a VCA SOLO button, if the channel is assigned to a VCA Group.
Intercancel or additive soloing is possible, with or without Input Priority, and solos
can be cleared with a single button press (SOLO CLEAR) at the master section.
The integral LED illuminates to indicate that a SOLO is active.
o
LLEEDD iinnppuutt mmeetteerriinngg
The channel is fitted with a dual 5-segment peak-reading bargraph meter, posi-
tioned next to each fader for maximum visibility and giving immediate and graphic
indication of incoming (pre-EQ) signals. The top (red) LED in the bar is configured
as a Peak LED, and monitors the signal path in three places, (input, pre-Mute and
post-fader) giving warning that the signal is exceeding +20dBu. The meter point is
jumper-selectable to be post-fader if required (see Chapter 2).
RReeaarrccoonn PPaanneell
The connections on the rearcon panel are as follows:
IINNPPUUTT LL aanndd RR XXLLRR
Pin 1 Gnd (Screen)
Pin 2 Hot (In-phase signal)
Pin 3 Cold(Out-of-phase signal)
IINNSSEERRTT SSEENNDD
(Balanced)
Tip Hot (In-phase signal)
Ring Cold (Out-of-phase signal)
Sleeve Gnd(screen)
IINNSSEERRTT RREETTUURRNN
(Balanced)
Tip Hot (In-phase signal)
Ring Cold (Out-of-phase signal)
Sleeve Gnd(screen)