Speco Technologies 4HD DVR User Manual


 
22
Press SEL button or double click to enter the menu. Then PTZ menu screen is displayed.
Figure 3.4.3. PTZ Control Setup Screen
Note: For speed dome cameras that support RS-485, connect them directly to the RS-485 port. If the
camera is controlled with RS-232C, use a RS-485 to RS-232C signal converter.
On the PTZ control setup screen, you can select or set the protocol type of the camera that is the same as
the one installed on the site. If the camera has a specific camera ID, select the camera ID using the control
button ( ).
The following options are available on the PTZ setup screen.
CHANNEL (channel number that the PTZ is connected to)
NAME (protocol type)
SPEED (19200, 14400, 9600, 4800, 2400)
ID (0-63)
3-4-3. Motion Zone Setup
Select MOTION ZONE using the control button ( ) and select either PARTIAL ZONE or FULL
ZONE using the control button ( ). And press the SEL button.
If FULL ZONE is selected, the motion setting screen is not displayed. Only set the level of sensitivity for
MOTION SENSITIVITY.