Topfield TF4000PVR VCR User Manual


 
39
VI-4 . Motorized DiSEqC 1.2
If you have DiSEqC 1.2 motorized system, then you can use the DiSEqC 1.2 functions.
. Satellite Name
A selection of satellite names that will be used to identify a motor position.
. Tuner Select
: Select a tuner, connected with DiSEqC 1.2 system.
. Frequency
: Selects the frequency to catch the strong signal.
. DiSEqC Command Mode
: Change the current mode between
User
and
Installer
modes.
-
User
: This mode is used to fine-tune the position of the motor for better reception.
-
Installer
: This mode is used to search for the position of a satellite manually.
. Movement
: In case of
User
mode, the movement is adjustable by fine-tuning.
In case of
Installer
mode, the movement is adjustable by
East
,
West
going
command.
00% Level
00% Quality
. Motor Control
-
Goto
: Moves the motor to the stored position of the selected satellite.
-
Store
: Stores the current position of the motor for the selected satellite.
-
Reset
: Resets all stored position of the motor relative to the “0” position (
Installer
mode only).
-
Recalculate
: Recalculates the position of the Stab Rotor motor.
-
Limit E
,
Limit W
: Limits east and west position.
-
Limit Off
: Removes the limitation.
-
Goto Ref
: Goes to reference.
. Channel Search
: After saving the DiSEqC configuration at the highest signal quality,
press button to start channel searching of the selected satellite.