A SERVICE OF

logo

BMC Software, Inc., Confidential and Proprietary Information
B-20 PATROL for BEA WebLogic User Guide
BEAWLS_SERVLET Application Class
ExecutionTimeAverage
Average execution time for this servlet. This is
calculated as ExecutionTimeTotal divided by
InvocationCount.
Collector: ServletDiscovery
basic con 800 - 900 900 -
1000
set by
coll
graph msec
ExecutionTimeHigh
Longest execution time for this servlet. This is the
slowest run time since the servlet was created.
Collector: ServletDiscovery
basic con undef undef set by
coll
graph msec
ExecutionTimeLow
Shortest execution time for this servlet.
Collector: ServletDiscovery
basic con undef undef set by
coll
graph msec
ExecutionTimeTotal
Total execution time for this servlet.
Collector: ServletDiscovery
basic con undef undef set by
coll
graph msec
InvocationCount
Number of times a servlet has been invoked.
Collector: ServletDiscovery
basic con 4000 -
6000
6000 -
10000
set by
coll
graph number of
times
BEAWLS_SERVLET_METHOD Application Class
AvgResponseTime
Average response time for this servlet to execute.
Collector: _WebAppRespColl
inst con 800 - 900 900 -
1000
set by
coll
graph msec
InvocationCount
Number of times this servlet was invoked during the
previous collection cycle.
Collector: _WebAppRespColl
inst con 4000 -
6000
6000 -
10000
set by
coll
graph number of
calls
InvocationRate
Frequency at which the servlet method was invoked
during the previous collection cycle (number of calls
per millisecond).
Collector: _WebAppRespColl
inst con undef undef set by
coll
graph calls per
millisecond
TotalResponseTime
Total response time for this servlet method during
the previous collection cycle.
Collector: _WebAppRespColl
inst con 1000 -
2000
2000 -
3000
set by
coll
graph msec
BEAWLS_SETUP Application Class
_monitorRegisterServer
Collector that discovers WebLogic instances. This
runs only five times after initialization.
basic coll none none 1200
sec
text none
Table B-1 Parameters in PATROL for BEA WebLogic when monitoring WebLogic Server 6.x,
7.0, or 8.1 (Part 17 of 19)
Parameter
Required
Configuration
Type
Warning
(Alarm1)
Alarm
(Alarm2)
Scheduling
Icon
Units