EverFocus 264x4 DVR User Manual


 
49
Auto Lock: Check the box and the events will be recorded in the write protected segment of the Hard Disk.
(DVR will lock a period of time when alarm happen, the length of time will depend on DVR setting)
Alarm Output: This will transmit a signal through one of the alarm outputs. It can be set to either “NONE
(not active), “1”, “2”, “3”, or “4”.
Output Type: Output action when motion is triggered.
Timeout: Alarm output lasts for the set time duration.
Permanent: Alarm will remain on until user presses “Enter” key on front panel.
Transparent: Alarm output continues as long as there is a motion event.
Trans+Timeout: Alarm output continues until event ends, then lasts for the set time duration.
Timeout Duration: Time duration selectable from 1 to 150 seconds.
Edit Motion Grid: Press this button to edit the motion grid (See
Figure 5-5 Camera Menu – Motion Grid Setting
).
Sensitivity: Set the threshold value for sensitivity. Select from 1 (lowest) to 10 (highest).
Min Area: To avoid false detections by small objects this value defines, how many grids have to be
detected for generating a motion event. Select a value between 1 (default) to 5 grids.
Delay: Filter function for avoiding false alarms (set to 1 for the easiest trigger)
Preview: Turn off display for motion grid
Set All: Press this button to select the entire area.
Clear All: Press this button to clear all the grids selected.
Save & Back: Press this button to save the motion grid setting and return to motion setting menu.
Cancel: Press this button to cancel all changes and return to motion setting menu.
How to select motion grid by mouse:
1. Select left-up grid 2. Select right-down grid. 3. The area between left-up and right-down
grid will be selected.