EverFocus 264x4 DVR User Manual


 
64
Record Stop:
Figure 5-18 Alarm & Event Menu – Event – Record Stop
Log: Check box to record events in the log.
Buzzer: Check box to enable buzzer when DVR stops recording.
Email Notify: Check box to enable email notification when DVR stops recording.
Network Alarm: Check box to send out a network alarm to client PC. (requires PowerCon software and
setting up Alarm Server in Network Setup menu)
Alarm Output: This will transmit a signal through one of the alarm outputs. It can be set to either “NONE
(not active), “1”, “2”, “3”, or “4”. (If an output is assigned to Record Stopped, any other events assigned for
that alarm output will automatically change to “None”)
Output Type: Output action when alarm is triggered.
Timeout: Alarm output lasts for the set time duration.
Permanent: Alarm will be continuously active until user presses “Enter” key.
Transparent: Alarm output remains active until event ends.
Trans+Timeout: Alarm output continues until event ends, then lasts for the set time duration.
Timeout Duration: The amount of time the buzzer sounds when DVR stops recording. Duration selectable
from 1 to 150 seconds.