Hyundai P224WK Flat Panel Television User Manual


 
3/36
DIGITAL SIGNAGE
1. Press Menu button. Menu items appear on the screen.
2. Press / button to move to "Multi" Icon.
3. Press button to select "Multi" Icon. "Multi Function" is highlighted
4. Press / buttons to move to "Heat Control".
5. Press or buttons to set up and change the Heat Control.
“Fan Control" - AS the fan operation options, following 3 options are available
- Off : Fan is idle in Off status.
- On : Fan is working in On-status.
- Auto :
Fan start working when the working temperatur
e is higher than the measured temperature.
• Fan active Temp -set up value to start the fan.
• Hysteresis- tolerance value of fan operation temperature.
• Temperature- measured current temperature by sensor affixed to PCB'A
How to Set the Heat
Control
"Heat control" allows you set up fan operation according to interior temperture of the product
Multi
Multi Function

Heal Control

U
Move
Enter
Menu
Multi
Fan Control : Off
Fan Active Temp : 50
°C
Hysteresis : 50
°C
Temprature : 50
°C
U
Move
Enter
Menu
DID_eng.indb 32 2009-09-15 오후 8:24:29