3 CONNECTIONS
3-1 Recording video signals from a camera
This section describes how to connect a camera and record camera signals. When more than one camera is connected, the
cameras must be synchronized. Multi-camera connections are discussed in the next section.
To AC 120 V, 50 Hz/
60 Hz
Connecting a camera
1. Connect the [MONITOR OUT] and [AUDIO OUT] connectors to the monitors video and audio connectors.
2. Connect [CAMERA IN] connector to the video cameras video output connector.
3. To record sound, connect a microphone amplifier to the [AUDIO IN] connector.
4. To record an alarm, connect the alarm sensor to the [ALARM IN 1] and [COM] signal input/output terminals.
5. After all connections are complete, connect the power cable to the [AC IN] socket and connect the plug to an AC 120 V outlet.
6. Turn ON all connected equipment, then turn the [POWER] switch on the rear panel to ON.
Menu switch setting
Example of settings when using an alarm sensor and recording audio.
DVR MODE
[REC QUALITY] set to N
[REC SPEED] set to 30
[AUDIO REC] set to ON
ALARM/SENSOR MODE
[REC MODE] set to ALARM
Reference: 5-3 Menu switch details on page 19.
Caution:
Before connecting or disconnecting any equipment,
turn the power of all connected equipment OFF.
CAMERA IN
MONITOR OUT
1
1
2
12
AUDIO
IN
AUDIO
OUT
RS-232C
POWER
SIGNAL GND
CAM SW
OUT
ALARM
IN1
SPARE
SPARE
SPARE
HDD
FULL OUT
ALARM
RESET
CLOCK
RESET IN
CLOCK
RESET OUT
EXT
REC IN
COM COM
ON OFF
I
O
AC IN 120 V
50 Hz / 60 Hz
Video camera
Amplifier
Microphone
Provided
power cable
Monitor
Alarm sensor
ALARM IN