Appendix E
Startup Data Sequences
The data on the following pages presents the startup data
sequences registered by the TracVision S2. The first section shows
the sequences registered by a system that is connected to an IRD
low-speed data port. The second section shows the sequences
registered by a system that is NOT connected to an IRD low-speed
data port. Both sections show two routines. One is the standard,
full initialization routine; the second is that registered by
TracVision S2 if it is turned on and acquires the satellite via the
“Instant On” operation (described in Section 3, “Using Your
TracVision S2”). These sequences can be recorded using the data
port and a PC.
E.1 System Connected to IRD Data
Standard Startup Sequence
?PGM
KVH TracVision S2 Rev X - Version X.XX - Serial Number XXXXXXXX
Limit Switch Test
Limit Switch Status: PASS-----------------PASS is expected
*** Initializing IRD ***
..
IRD STATUS: PASS DSS --------------------PASS is expected with success2ul IRD identification
Saved Sat Pos: EL = 33.4
*** Averaging Background Noise ***
+POS: 45.0 26.6 735
+POS: 57.9 20.0 1004
+POS: 232.0 20.0 812
+POS: 25.6 20.0 898
Average Noise Level = 957
Noise Threshold = 1781
Saved Sat Pos: EL = 33.4
*** Entering Search Mode 1 ***
+POS: 80.9 32.1 1217
+POS: 44.6 33.4 853
Satellite Found: AZ = 327.7, EL = 33.4, RF = 2476
+POS: 306.4 33.4 1020
*** Initializing Finetune ***-------------Peaking the satellite signal
+POS: 327.7 33.4 2827