13.0 SPECIFICATIONS
Power Source: 100-230 VAC, 50/60 Hz. (The included power cord is
used for 120 VAC, 60 Hz)
Power Consumption: Approximately 20 watts
Rating:
ALM/CALL/MODE Active: “Low” level, maximum current 50 mA (+5
VDC)/10 mA (+24 VDC)
Non-active: Open, maximum voltage +24 VDC
SET/RST/REC Active: When terminals are short-circuited or “Low”
level voltage applied
Non-active: Open, max. Voltage +17 VDC
CLK Recording: A pulse of the frequency division ratio
selected in REAR TERMINAL menu
Tape Format: S-VHS/VHS 1/2" width high-density video cassette
tape
Television System: 525 lines, 60 field NTSC-type color system
Video Recording System: 2 rotary heads, azimuth helical scanning system
Luminance Signal: Frequency modulation recording
Color Signal: Low frequency conversion, sub-carrier phase shift
recording
Audio Track: 1 track
Tape Speed and
Recording Time
(with T-120 cassette):
Record Record Time Record Time Field (Picture) Tape Drive Audio Recording
Mode (T-120/ST-120 Tape) (T-160/ST-160 Tape) Recording Rate Mode Capability
2H 2 Hrs. 2 Hrs.40 Mins. 60 Fields/Sec Continuous Yes
6H 6 Hrs. 8 Hrs. 60 Fields/Sec Continuous Yes
L18H 18 Hrs. 24 Hrs. 20 Fields/Sec Continuous(Slow) Yes
L24H 26 Hrs. 34 Hrs.40 Mins. 4.6 Fields/Sec Continuous(Slow) Yes
48H (SP) 50 Hrs. Not Recommended 2.4 Fields/Sec Time-lapse No
48H (EP) 54 Hrs. Not Recommended 6.7 Fields/Sec Time-lapse No
72H (SP) 74 Hrs. Not Recommended 1.6 Fields/Sec Time-lapse No
72H (EP) 78 Hrs. Not Recommended 4.6 Fields/Sec Time-lapse No
96H (SP) 98 Hrs. Not Recommended 1.2 Fields/Sec Time-lapse No
96H (EP) 102 Hrs. Not Recommended 3.5 Fields/Sec Time-lapse No
120H (SP) 122 Hrs. Not Recommended 0.98 Fields/Sec Time-lapse No
120H (SP) 126 Hrs. Not Recommended 2.9 Fields/Sec Time-lapse No
168H (SP) 170 Hrs. Not Recommended 0.70 Fields/Sec Time-lapse No
168H (EP) 174 Hrs. Not Recommended 2.1 Fields/Sec Time-lapse No
0H (one-shot) 1199Hrs.* Not Recommended 0.10 Fields/Sec Interval Time-lapse No
* Programmed for: 1 Field-per-Shot @ 10-Second Interval Rate