Pelco DX3016-060 DVR User Manual


 
Pelco Manual C681M-D (2/02) 83
Inputs/Outputs
POWER ON: Input for power ON. Low input state is power off; high input
state is power on.
POWER OFF: Input for power OFF. Low input state is power off.
ALARM IN (1-9): Inputs for starting alarm recording. Active: When terminals
are short-circuited or “Low” Level voltage is applied.
Non active: Open.
CLOCK ADJ: Input for adjusting clock. Active: When terminals are short-
circuited or “Low” Level voltage is applied. Non active: Open.
REC: Input to start recording. Active: When terminals are short-
circuited or “Low” Level voltage is applied. Non active: Open.
GND: Ground.
ALARM OUT: Output for use while alarm recording is under way.
Active: “Low” Level. Maximum drive current: 7 mA DC.
MODE OUT: Output for indication of selected recording mode.
Non-active: Open. Maximum voltage: +24V DC.
DC 5V OUT: Output for DC 5V OUT.
CALL OUT: Output for external warning device. Active: ON. Maximum
drive current: 7 mA DC.
CALL OUT GROUND: Ground for external warning device. Non active: Open.
Maximum voltage: +24VDC.
GENERAL
Operating Temperature: 41° to 104°F (5° to 40°C).
Relative Humidity: Maximum 80%
Dimensions: 16.7 (W) x 15.0 (D) x 4.45 (H) inches
(42.5 x 38.0 x 11.3 cm)
Unit Weight
DX3009 models: 15.7 lb (7.1 kg)
DX3016 models: 17.9 lb (8.1 kg)
Connectors
Push-in terminal: POWER ON, POWER OFF, ALARM IN, CLOCK ADJ, REC
inputs
Ground, CALL OUT ground
ALARM OUT, MODE OUT, DC 5V OUT, CALL OUT outputs
BNC: Video input/output
SVHS: Video output
DB9: RS-232C for connection with personal computer
50-pin D-type: SCSI
(Design and product specifications subject to change without notice.)