54 Pelco Manual C673M (2/01)
SEARCH TECHNIQUES
COUNTER MEMORY STOP
This feature rewinds a tape until the counter on the fluorescent display reaches 00000 and
stops. (NOTE: When the counter indicates 00000, COUNTER MEMORY STOP on the
Search Function menu cannot be selected.)
1. Press the SEARCH button once. The Search Function menu appears with COUNTER
MEMORY STOP highlighted. The counter memory stop indicator (M) on the fluores-
cent display lights.
To exit the Search Function menu without rewinding, press STOP.
2. Turn the SHUTTLE ring right. The VCR starts rewinding the tape.
3. Press STOP to quit rewinding.
SKIP SEARCH
The VCR automatically inserts an index signal at the beginning of each alarm recording, so
the start of each alarm can be located. During fast forwarding or rewinding, the VCR plays
back a tape (in 2H, 6H, or 8H mode) for about four seconds where an index signal is
recorded. It repeats this process until reaching the end or beginning of the tape.
1. Press the SEARCH button enough times to highlight SKIP SEARCH on the Search
Function menu. The skip search indicator (SKIP) on the fluorescent display lights.
To exit the Search Function menu without searching, press STOP.
2. Turn the SHUTTLE ring right (search forward) or left (search backward) to start
searching.
3. When you find a picture you want to view, press PLAY.
4. To quit searching, press STOP.
The index signal may be hard to find under some recording conditions. Skip search may
not function if the interval between two alarm recordings start times is too short. Refer to
Table G for minimum intervals.
Audio output is muted during skip search.
Figure 31. Skip Search
00490
ALARM
RECORDING
ALARM
RECORDING
PRESENT POSITION
INDEX
FAST
FORWARD
FAST
FORWARD
INDEX
APPROX. 4 SEC.
PLAYBACK
APPROX. 4 SEC.
PLAYBACK
FAST
FORWARD