Runco CW-42HD Flat Panel Television User Manual


 
Installation
Runco CinemaWall Owner’s Operating Manual 17
PRE
L
IMINAR
Y
VentilationIf you are mounting the CinemaWall in an enclosure, leave at least 2 inches (50 mm) of
space on all sides between it and surrounding objects, as shown in
Figure 3-2. This allows
heat to disperse, maintaining the proper operating temperature.
Figure 3-2. Ventilation Requirements for Enclosure Mounting
Other ConsiderationsOther considerations and tips that can help improve your installation, avoid damage and
prolong operating life:
Keep the ambient temperature constant and below 35°C (95°F). Keep the display away
from heating and/or air conditioning vents. Changes in temperature may cause drifts in
the display circuitry, which may affect performance.
Keep the CinemaWall away from devices that radiate electromagnetic energy such as
motors and transformers. Common sources of these include slide projectors,
speakers, power amplifiers and elevators.
Handle the unit carefully when installing it. When carrying it, use the built-in handles; DO
NOT touch or hold the screen face.
Set the unit away from heat, excessive dust, and direct sunlight.
Protect the inside of the unit from liquids and small metal objects. In case of accident,
unplug the power cord and have it serviced by an authorized Runco Service Center.
Do not hit or scratch the panel surface as this causes flaws on the surface of the
screen.
For correct installation and mounting it is strongly recommended to use a trained,
authorized dealer.
To avoid sulfurization, it is strongly recommended not to place the unit in a dressing
room in a public bath or hot spring bath.
50
mm
(2")
50
mm
(2") 50
mm
(2")
Wall
Wall
50
mm
(2")
50
mm
(2")