Samsung SHR-4160P DVR User Manual


 
5-20
Quality
Recording resolution will be determined.
HH(Very High)/H(High)/N(Normal)/L(Low).
Note
The resolution Full D1 can be set from the 7.5ips(NTSC)/6.25ips(PAL) recording
frame.
The resolution Halfl D1 can be set from the 15ips(NTSC)/12.5ips(PAL) recording
frame.
The resolution CIF can be set from the 15ips(NTSC)/12.5ips(PAL) recording frame.
But, if the resolution is CIF and the number of camera is odd number,
30ips(NTSC)/ 25ips(PAL) is supported.
Rate
Determines Frame Rate to be recorded. Frame Rate means the number of screen
recorded every second.
Set to 15ips(NTSC)/12.5ips(PAL), the system records too many screens per sec-
ond and play continues intermittently since recording is more detailed. This is
appropriate for concentrated monitoring zone setup.
Set to the one of 30ips / 15ips / 10ips / 7.5ips / 5ips / 3ips / 1ips(NTSC)
Set to the one of 25ips / 12.5ips / 8.33ips / 6.25ips / 5ips / 2.5 ips / 1ips(PAL)
Pre-Event
Post-Event
Records the situation until Event is issued.
Off : No recording
5sec/ 10sec/ 20sec/ 30sec : The recording time options before Alarm issue
Records the situation since Event is issued.
Off : No recording
5sec/ 10sec/ 20sec/ 30sec/1min/3min/5min/10min/20min :
To this, the recording time after Alarm issue is set.
Pre-Event Section
Event occurred point of time
Post-Event Section
Event occurred point of time