TANDBERG 1500MXP Flat Panel Television User Manual


 
6 Appendix
131
6.8 Appendix 8
Connecting the system to the Switched 56 network
Using Telesync TS-256 SW56/ISDN adapter
Connecting the system to the SW56 network using a Telesync Adapter is described below.
There are different Telesync Adapters for different configurations of SW56 networks. The
network types tested with the system are SW56 2Wire and 4Wire.
Connecting
Connect the system ISDN1 cable to the BRI S/T interface on the Telesync Adapter. Connect
the two SW56 cables from the Telesync adapter Line 1 and Line 2 to the SW56 network.
Configuration of the system
Select network type to National ISDN.
LINE 1 SETUP
NUMBER1:
NUMBER2:
SPID1:
SPID2:
program with number from the first SW56 line
program with number from the second SW56 line
program with number from the first SW56 line
Leave blank
How to call
It is important to use Restrict (56k). Select Restrict (56k) in Call Settings in the Call menu
(select the field next to the phone book button in the call menu). A second number field will
appear when ISDN is selected for Net within Call Settings and you choose bandwidth 128
kbps. Enter the second number in the call settings menu.