Trimble Outdoors Part Number 45005-00-ENG TV Antenna User Manual


 
A-78 Acutime 2000 Synchronization Kit User Guide
Trimble Standard Interface Protocol
A
0xBB Command Packet BB
Set Primary Receiver Configuration
TSIP command packet BB contains the primary receiver
configuration parameters.
The Ace UTC and Acutime 2000 store 3 independent sets of
configuration parameters. These are designated as the "Mobile",
"Survey" and "Timing" configurations.
The active configuration is determined by the survey state:
When the survey state changes, the receiver automatically switches to
the new configuration. Only the active configuration can be
programmed.
To program configurations, switch the active configuration by
changing to the appropriate survey state using packets 8E-A6 and 8E-
A9, update the configuration (BB), and save settings (8E-26).
There are restrictions to the dynamics code and operating dimension
settings, which take effect when survey is enabled, ensuring that the
receiver performs a valid survey and enters a timing mode afterwards.
The following table shows valid settings for each configuration.
Table A-67 Survey State Configurations
Survey State Active Configuration
Survey Disabled Mobile
Survey Active Survey
Survey Complete Timing