Trimble Outdoors Part Number 45005-00-ENG TV Antenna User Manual


 
Acutime 2000 Synchronization Kit User Guide A-89
A Trimble Standard Interface Protocol
0x8E-20
Command Packet 8E-20
Request Last Fix with Extra Information
This packet requests packet 8F-20 or marks it for automatic output. If
only the first byte (20) is sent, an 8F-20 report containing the last
available fix will be sent immediately. If two bytes are sent, the
packet is marked/unmarked for auto report according to the value of
the second byte.
!
Note – Auto-report requires that superpacket output is enabled. Refer
to command packet 35. This packet must also be enabled with
packet 8E-4D.
0x8E-26
Command Packet 8E-26
Write Receiver Configuration to EEPROM
This command packet causes the current configuration settings to be
written to the EEPROM. It also generates a report packet 8F-26. This
packet contains only a single byte: the subpacket ID.
0x8E-41
Command Packet 8E-41
Manufacturing Operating Parameters
This packet is used to request the manufacturing parameters stored in
nonvolatile memory. The packet contains only a single byte, the
subpacket ID. The receiver returns packet 8F-41.
Table A-73 Command Packet 8E-20
Byte # Item Type Value
0 Sub-packet ID BYTE 0x20
1 Mark for Auto-report BYTE 0 = do not auto-report
1 = auto-report