Trimble Outdoors Part Number 45005-00-ENG TV Antenna User Manual


 
Acutime 2000 Synchronization Kit User Guide A-83
A Trimble Standard Interface Protocol
0xBB Report Packet BB
Report Receiver Configuration
TSIP report packet BB is used to report the GPS Processing options.
For information about the data formats, see command packet BB.
0xBC Command Packet BC
Set Port Configuration Parameters
TSIP command packet BC is used to set the communication
parameters on Port 1 and Port 2. The table below lists the individual
fields within the BC packet.
Flow control is not supported. Please refer to section A.2 “Physical
Interface Characteristics” for details on the capabilities of each port
on the Ace UTC and Acutime 2000.
Table A-70 Command Packet BC
Byte # Item Type Value Meaning Default
0 Port Number BYTE 0
1
0xFF
Port 2 / Port B
Port 1 / Port A
current port
1 Input Baud
Rate
BYTE 0
1
2
3
4
5
6
7
8
9
None
110 baud
300 baud
600 baud
1200 baud
2400 baud
4800 baud
9600 baud
19200 baud
38400 baud
9600
2 Output Baud
Rate
BYTE As
above
As above 9600
3 # Data Bits BYTE 2
3
7 bits
8 bits
8 bits