VXI VT1529A/B Universal Remote User Manual


 
VT1422A Command Reference 317Chapter 7
OUTPut
OUTPut:SHUNt?
OUTPut:SHUNt? (@<channel>) returns the status of the shunt resistance on the
specified Strain SCP or RSC channel.
Parameters
Comments The <channel> parameter must specify a single channel only.
If <channel> specifies a non strain SCP or RSC, a 3007 "Invalid signal
conditioning plug-on" error is generated.
Returned Value: Returns 1 or 0. The data type is uint16.
Related Commands: OUTP:SHUNT
Send with VXIplug&play Function: hpe1422_cmdInt16_Q(...)
Usage OUTPUT:SHUNt? (@116)
Check status of shunt resistance on
channel 16
OUTPUT:SHUNt? (@10124)
Check status of shunt resistance on
VT1529A/B channel 0124
OUTPut:SHUNt:SOURce
OUTPut:SHUNt:SOURce <select>,(@<ch_list>) selects the source of the bridge
shunt resistance for a VT1529A/B Remote Strain Bridge Conditioning unit. The
VT1529A/B has an internal shunt resistor and also supports an external user supplied
resistor.
Parameters
Comments
If <ch_list> specifies a non VT1529A/B strain SCP, a 3007 "Invalid signal
conditioning plug-on" error is generated.
Only one channel on each VT1529A/B needs to be specified since a single
resistor is used for all channels in the module.
When Accepted: Not while INITiated
Parameter
Name
Parameter
Type
Range of
Values
Default
Units
channel channel list (string) 100 - 15731 none
Parameter
Name
Parameter
Type
Range of
Values
Default
Units
select discrete (string) INTernal | EXTernal none
ch_list channel list (string) 10000 - 15731 none