outage-retrain
Use the outage-retrain command to cause the SHDSL interface to force the SHDSL retrain sequence
(which takes the line down temporarily) if the interface detects more than ten consecutive errored seconds.
A retrain is forced in hopes that the newly retrained line will achieve better performance than the previous
training state. Use the no version of the command to disable this feature.
Syntax Description
No subcommands.
Default Values
By default, this feature is disabled.
Applicable Platforms
This command applies to the NetVanta 1000R, 3000, and 4000 Series units.
Command History
Release 3.1 Command was introduced.
Usage Examples
The following example forces a retrain sequence on the SHDSL interface:
(config)#interface shdsl 1/1
(config-shdsl 1/1)#outage-retrain