Custom tests for software not on the default list may be created. A single test can be created to run
checks for one or MORE software pieces within the same rule. Each set of Process Running and
File Exists checks will have their own Success/Failure results.
To create a new antivirus/spyware rule:
Step 1: Select Antivirus/Spyware Rules from the components tree and click the Add New button
Step 2: Name the rule and provide a description
Step 3: Select the trigger for the rule
Startup - run tests at system startup
Location Change - run the tests whenever the ZSC switches to a new location
Timer - integrity tests may be performed on a defined schedule by the minute,
hour, or day. Set the time for how often the tests will run
Step 4: Click Save.
Step 5: Define the Integrity Tests (see “Integrity Tests” on page 138)
Step 6: Repeat the above steps to create a new antivirus/spyware rule
Associate Existing Antivirus/Spyware Rules:
Step 1: Select Antivirus/Spyware Rules and click Associate Component
Step 2: Select the desired Rule(s) from the list
Step 3: The tests, checks, and results may be re-defined
Note:
Changing the settings in a shared component will affect ALL OTHER instances of this same component.
Use the Show Usage command to view all other policies associated with this component.
Step 4: Click Save
Step 5: Integrity tests and checks will be automatically included and can be edited as necessary