Psion Teklogix WORKABOUT PRO With Windows Mobile 2003 SE User Manual 269
Chapter 8: Expansion Modules
Enabling The SE 1223HP Scanner
• Fit the scanner module over the back of the WORKABOUT PRO
–it
replaces the back plate of the unit.
• Fasten the module in place with the screws provided. Tighten the screws to
a torque of 3 lbs-in (3kgf-cm).
• Slide the SW1401 power switch to the right to turn power back on, and
replace the end-cap, backplate and battery. Tighten the end-cap screws to a
torque of 3 lbs-in (3kgf-cm).
Figure 8.10 Scanner Module Installed In WORKABOUT PRO
8.1.6.1 Enabling The SE 1223HP Scanner
• Simultaneously, press and hold down the <BLUE> <ENTER> and left
<SCAN> keys for a minimum of 6 seconds. A
Command> prompt is
displayed on the WORKABOUT PRO screen.
• Type s to display the
Scanner> prompt. A list of supported scanners is
displayed.
• Type 2 and press <ENTER> to activate scanner type SE 1223HP.
• At the
Command> prompt, type 1 (one) to reboot the unit to
Windows Mobile 2003 SE.
8.1.7 Installing An SE 923HP Scanner
Warning: Anti-static devices MUST BE USED during the installation of
this scanner module. If unavailable, discharge static from your
body by touching a grounded metallic object before
opening any
covers on the unit.