EverFocus ephd04 DVR User Manual


 
EPHD04+ HDcctv DVR
69
6.4.2 Event
You can configure the event settings and enable the Buzzer or Email alert for notifications.
The event options include: Fan Failure, HD Temperature, HD Failure, HD Full, HD Off, Power
Loss and Network Loss.
6.4.2.1 Fan Failure
Figure 6-11
Log: Check the box to record alarm events to log data.
Buzzer: Check the box to enable buzzer when fan is not working.
Email Notify: Check the box to send email notification when an alarm event is detected. Email
operation requires valid email entered in the Email setup menu (see 6.6.2 Email).
Network Alarm: Check the box to send out a network alarm to a client PC when an alarm
event occurs. This feature works with EverFocusCMS software, PowerVideo Plus. You will
need to configure the Alarm Server for the DVR to send network alarms to the client PC (see
6.6.4 Alarm Server).
Alarm Output: Select an alarm output number. When an alarm is triggered, the signal will be
transmitted through the selected alarm output relay.
Output Type: Output action will be Transparent and cannot be changed (alarm output
remains as long as the alarm condition is active).