2.5.2 Checking Out the System Without an IRD
Data Connection
To ensure that the system is configured and operating properly,
you will need to check the data provided in the system’s startup
routine.
To do so, you need to connect a PC to the antenna baseplate’s
maintenance port. The diagnostics procedure requires terminal
emulation software such as Windows Hyperterminal or
PROCOMM. Use the settings appropriate to your application.
1. Connect one end of a PC data cable to the
maintenance port connector on the switchplate
(see Figure 2-10). To access this connector, you may
need to remove the switchplate from the mounting
surface. Connect the other end to the serial port on
the PC (a 9-pin/25-pin connector adapter may be
needed for some PCs).
2. Open the terminal emulation software and
establish the following settings:
• Bits per second: 9600
• Data bits: 8
• Parity: None
• Stop bits: 1
• Flow control: None
2-12
A Guide to TracVision LF/SF
Figure 2-11
PC Data Cable DB9 Connector
Figure 2-10
Switchplate Maintenance Port
Maintenance Port
(DB9 Connector)