RS-232C
$
Search control commands
Sends data of computer Return data from VTR Description of command
[STX] SCP:data [ETX]
Parameters
data = ghmmssff
O
When CTL data is to be used
as the reference
g = Blank: With a positive value
– sign: With a negative value
h = 0
9: Hours
mm = 00 59: Minutes
ss = 00 59: Seconds
ff = 00 29: Frames
O
When TC data is to be used as
the reference
gh = 00 23: Hours
mm = 00 59: Minutes
ss = 00 59: Seconds
ff = 00 29: Frames
[STX] SCP [ETX] Searches the counter value which was designated by the
parameter.
Playback is commenced upon completion of the search.
If the designated position is an illegal position (the target
position does not exist), error code ER122 will be returned
from the VTR, which is then set to the STOP mode.
When the OSP (STOP) command or OEJ (tape EJECT)
command is issued during operation, error code ER123 is
returned from the VTR.
If the VTR’s operation mode has been changed by
operating the controls on its front panel, error code ER121
will be returned from the VTR.
If the tape end position is reached during operation, error
code ER120 will be returned from the VTR.
When data differing from the data used as the reference
has been sent, error code ER001 will be returned from the
VTR.
<Note>
This command is ignored while a search control command
is being processed and in any of the following modes.
EJECT, REC, REC PAUSE, INSERT, INSERT PAUSE
[STX] SCS:data [ETX]
Parameters
data = ghmmssff
O
When CTL data is to be used
as the reference
g = Blank: With a positive value
– sign: With a negative value
h = 0 9: Hours
mm = 00 59: Minutes
ss = 00 59: Seconds
ff = 00 29: Frames
O
When TC data is to be used as
the reference
gh = 00 23: Hours
mm = 00 59: Minutes
ss = 00 59: Seconds
ff = 00 29: Frames
[STX] SCS [ETX] Searches the counter value which was designated by the
parameter.
The STILL mode is established upon completion of the
search.
If the designated position is an illegal position (the target
position does not exist), error code ER122 will be returned
from the VTR which is then set to the STOP mode.
When the OSP (STOP) command or OEJ (tape EJECT)
command is issued during operation, error code ER123 is
returned from the VTR.
If the VTR’s operation mode has been changed by
operating the controls on its front panel, error code ER121
will be returned from the VTR.
If the tape end position is reached during operation, error
code ER120 will be returned from the VTR.
When data differing from the data used as the reference
has been sent, error code ER001 will be returned from the
VTR.
<Note>
This command is ignored while a search control command
is being processed and in any of the following modes.
EJECT, REC, REC PAUSE, INSERT, INSERT PAUSE