Panasonic AJ-D950 DVR User Manual


 
– 66 –
Servo reference setting tables
The servo reference signal is switched as shown in the tables below depending on the servo
reference setting, deck mode and what input signal is available. When the mode is
transferred to editing or recording/playback, the image may be disturbed and the transfer
may be delayed if the references during playback and recording do not match.
During playback or special playback
SERVO REF
Input signal status
Reference signal
on the setup menu
(servo reference)
No. 304 position VIDEO IN signal REF IN signal
REF IN signal
AUTO
×
Internal sync signal
×
REF IN signal
××
Internal sync signal
REF IN signal
EXIT
×
Internal sync signal
×
REF IN signal
××
Internal sync signal
During recording or editing
SERVO REF
Input signal status
Reference signal
on the setup menu
(servo reference)
No. 304 position VIDEO IN signal REF IN signal
VIDEO IN signal
AUTO
×
VIDEO IN signal
×
REF IN signal
××
Internal sync signal
REF IN signal
EXIT
×
Internal sync signal
×
REF IN signal
××
Internal sync signal
” denotes that the signal is supplied: “×” denotes that the signal is not supplied.
When “BB” or “CB” is set for the setup menu No. 600 and internal signal generation has been
selected, the REF IN signal serves as the servo reference when the REF IN signal is
provided and the internal sync signal serves as the servo reference when the REF IN signal
is not provided.