Pelco DX4800 DVR User Manual


 
C4655M (2/11) 83
APPENDIX J: FACTORY DEFAULTS
You can reset the HVR to its original factory settings by importing or exporting the configuration settings. Some options cannot be reset (date,
time, daylight saving, time zone, and user password settings).
Configuration Import: Imports the HVRs configuration data from the USB memory stick.
Configuration Export: Exports the configuration data from this HVR to the USB memory stick.
NOTE: If you use a USB memory stick or USB HDD for configuration import/export you must disconnect the other external USB devices.
Table I. Factory Default Settings (1 of 6)
Menu Submenu Property Setting
Factory
Default Setting
Camera Camera Channel (Ch) 01 to 16, IP1, IP2 (cannot be changed) 01 to 16, IP 01, IP 02
Name CH 01 to CH 16, IP 01, IP 02 CH 01 to IP 02
Audio OFF, 01 to 04 OFF
Disable OFF, ON OFF
PTZ* Channel CH 01 CH 01
Port NONE NONE
Control ID 00* N/A
Protocol PELCO_D* PELCO_D
Baud Rate 9600* 9600
PTZ Test N/A* N/A
IP Camera Channel IP 01 IP 01
Vendor NONE, AXIS, PELCO NONE
Model Name N/A* N/A
IP Address N/A* N/A*
User Name N/A* N/A
Password N/A* N/A*
Port 554* 554
Test N/A* N/A
ATM/POS Interface Device DEFAULT, AVE Hydra DEFAULT
Camera CH 01 to CH 16 CH 01
Baud rate 1200 to 115200 9600
Data Bits 5 to 8 8
Stop Bits 1 1
Parity NONE NONE
Storage Overwrite ALL ALL
Full Warning OFF OFF
Auto Delete OFF OFF
Event Partition 50% 50%
N/A* FORMAT FORMAT
*This setting is only available when an associated setting is selected.