Pelco Manual C671M (1/01) 55
MECHANICAL
Heads
Video: 4 rotary heads
Audio/Control: 1 stationary head
Erase: 1 full-track head
Motors: 3 direct drive (drum, capstan)
Connectors
ALM Input: Screw terminal for starting alarm recording
RST Input: Screw terminal for finishing alarm recording or for adjusting
on-screen clock
REC Input: Screw terminal for starting/finishing recording or for series
recording
GND: Screw terminal for ground
ALM Output: Screw terminal for output while alarm recording is underway
CLK Output: Screw terminal to command camera switching
MODE Output: Screw terminal for indicating the VCR’s selected mode
CALL Output: Screw terminal for external warning device or for series recording
GENERAL
Operating Temperature: 41° to 104°F (5° to 40°C)
Relative Humidity: Maximum 80%
Dimensions
(JOG dial Included): 16.7 (W) x 12.3 (D) x 3.7 (H) inches (42.5 x 31.3 x 9.5 cm)
Weight: 9 lb (4.2 kg)
Weight and dimensions shown are approximate.
(Design and product specifications subject to change without notice.)
Table I. Tape Speed and Recording Time (T-160 Cassette)
Mode Record Speed Recording Recording Video Audio Tape
Time (mm/s) Interval Fields Signal Signal Drive
(hours) (s/field) (per second)
8H (EP) 811.12 0.0167 60 Continuous Recordable Continuous
L24H (EP) 24 3.71 0.050 20 Time-lapse Recordable Continuous (slow)
L40H (EP) 40 2.22 0.083 12 Time-lapse Recordable Continuous (slow)