Sanyo DSR-3709P DVR User Manual


 
MENU-SPECIFIC SETTINGS2
30 English
NETWORK
SETTINGS
NETWORK
CONTROL
ETWORK
OPERATION
DVR VIEWER
Set the permission for overwriting to recording areas or the
remaining-space warning level as described below.
When the normal recording area has been filled with data,
this setting dictates whether recording will be stopped or
continued by overwriting the recorded images currently
stored on the hard disk.
1 Select “OVERWRITE” for normal
recording area from the pull-down menu
on the screen.
[Settings] ( indicates default setting)
When the alarm recording area has been filled with data,
this setting dictates whether recording will be stopped or
continued by overwriting the recorded images currently
stored on the hard disk.
2 Select “OVERWRITE” for alarm
recording area from the pull-down menu
on the screen.
[Settings] ( indicates default setting)
In situations where the overwrite setting for the normal
recording area and the alarm recording area is “OFF”, you
can have the unit issue a warning as soon as the
remaining space in either of these areas reaches a specific
level. (JP. 37)
The following section describes how to set the level at
which the warning will be issued.
(This level is common for the normal recording area and
the alarm recording area.)
3 Set the remaining-space warning level
from the pull-down menu on the screen.
Setting range: 1% to 10% (in units of 1%)
z If the overwrite setting for the normal recording area
and the alarm recording area is “ON”, the remaining-
space warning level will be displayed as “**” and setting
will not be possible.
This setting is used when connecting multiple digital video
recorders.
Series recording can be used to ensure that, when the
capacity of the normal recording area or alarm recording
area is reached, recording continues automatically on the
next digital video recorder.
4 Set “SERIES REC” from the pull-down
menu on the screen.
[Settings] ( indicates default setting)
You can set the storage period for images. When the set
period has expired, the corresponding data will be
automatically deleted.
5 Set “AUTO DELETE” from the pull-down
menu on the screen.
[Settings] ( indicates default setting)
5. RECORDING CONDITIONS SET
Setting overwriting permission for the normal
recording area
Setting Description
OFF
Recording is stopped when the normal recording area
has been filled with data.
ON
When the normal recording area has been filled with
data, overwriting from the beginning of this area will
start automatically.
Setting overwriting permission for the alarm
recording area
Setting Description
OFF
Recording is stopped when the alarm recording area
has been filled with data.
ON
When the alarm recording area has been filled with
data, overwriting from the beginning of this area will
start automatically.
RECORDING CONDITIONS SET
NORMAL RECORDING AREA
ALARM RECORDING AREA
OVERWRITE :
OVERWRITE :OVERWRITE :
ON
ON
AUTO DELETE :
OFF
SERIES REC :
OFF
SAVE
REMAINING DISK WARNING : %
**
1
3
5
6
4
2
Setting the remaining-space warning level
Setting series recording
Setting Description
OFF Series recording is disabled.
ON Series recording is enabled.
Setting the auto delete
Setting Description
OFF Auto delete is not to be set.
1 -99
DAYS
You can set the storage period for recorded data
within a range of “1 DAY” - “99 DAYS” (in full days).
e00_l8hbe_xe_nw_7.book Page 30 Friday, November 5, 2004 11:01 AM