Sony KL-W9000 Projection Television User Manual


 
– 29 –
KL-W7000/W9000
RM-Y980
OP (Others)
Item Register Name Range Standard Values Typical Standard Values
Display
0 OSDH Display H Position 0-63 10 (VIDEO) 7(RGB) 2 Kinds (VIDEO, RGB)
1 OSDV Display V Position 0-63 7 (VIDEO) 7(RGB) 2 Kinds (VIDEO, RGB)
2 ASHT Auto Shut Off 0,1 Not used 0: OFF, 1: ON
3 CPWR CH Power ON Not used Not used
4 AGCH AGC Voltage High 0-15 Not used Not used
5 AGCL AGC Voltage Low 0-15 Not used Not used
6 DBSS DBS Category Yes/No Not used Not used
7 EDCK EDTV FULL Mode Detection 0,1 Not used Not used
8 AION AI AUTO 0,1 Not used Not used
9 K Picture Adjusting Variable K 0-7 1 Don't set “0” (Actual value is
1/8~7/8)
10 L Picture Adjusting Variable L 0-7 0 0~7 is converted into 1~8 in actual use.
11 LENS Display only 0 Lens focus adj.
12 PANEL 0:Green, 1:Red, 2:Blue, 3:White 0-3 Panel position adj.
13 WHITE APL 0-1 White balance adj. (0: GAIN, 1: BIAS)
14 WIND Display only 0 Window signal
15 STEP Display only 0 00: Normal, 01: Pattern 1,
02: Pattern 2
16 EDFL EDTV FULL Detection ON 0,1 Not used Not used
17 BC g_bs_search [0] 1-15 Not used Not used
18 TIME Lamp Counting Timer Current time count and 0 time are
displayed alternately with UP/DOWN
19 FMTL fh of distinction difference range 0 ± ((3+FHTL) ×0.2) kHz
20 FVTL fv of distinction difference range 0 ± (1.0+FVTL) Hz
21HV1 Threshold of scanning line 0-15 (505+ (5×HV1)) lines
distinction (low)
22 HV2 Threshold of scanning line 0-15 (555+ (5×HV2)) lines
distinction (high)
23 MINH fh of the frequency correspond 0-31 20+ ((3+FHTL) ×0.2) kHz
to MIN
24 MAXH fh of the frequency correspond 0-31 42+ ((3+FHTL) ×0.2) kHz
to MAX
25 MINV fv of the frequency correspond 0-15 (42+MINV) Hz
to MIN
26 MAXV fv of the frequency correspond 0-15 (77+MAXV) Hz
to MAX
27 FHAG Equivalence frequency of fh 0-15 FHAG (20×FHAGms)
changed detection
28 FVAG Equivalence frequency of fv 0-15 FHAG (20×FVAGms)
changed detection
29 NSAG Equivalence frequency of 0-15 Not used
non-signal detection (on signal)
30 FHMJ fh difference range of before 0-7 ± ((1+FHMJ) ×0.2) kHz
the signal distinction
31 FVMJ fv difference range of before 0-7 ± ((3+FVMJ)
the signal distinction
TP (Model Discrimination)
Item Display Register Name Range Standard Values Typical Standard Values
0 WIDE HH 0,1 Not used
1 TIME TIMER 0,1 0,1 Fan stop time switching
0: 10 min (normal), 1: 10 sec
2 KL37 KL-W7000 model 0,1 0,1 0: KL-W9000 1: KL-W7000